SN-Y01E OTR Tester

SN-Y01E OTR Tester

The three chamber oxygen permeability tester can simultaneously detect three samples at a time, with higher detection efficiency. Oxygen permeability tester, also known as oxygen permeability meter, is suitable for testing the oxygen permeability performance of films, sheets, paper, packaging and related materials in the fields of food, medicine, medical equipment, daily chemical, photovoltaic electronics, etc. It provides a wide range and high efficiency oxygen permeability detection for high, medium and low oxygen barrier materials.
Send Inquiry
Product Introduction

Standards

ASTM D3985,ASTM F1307,ASTM F1927(Optional),GB/T 19789,GB/T 31354,DIN 53380-3,JIS K7126-2-B,YBB 00082003-2015

Application Fields

Packaging | Food | Pharmaceuticals | New Materials | Chemical Industry | Printing

Intended Use

It is suitable for the oxygen permeability performance testing of films, sheets, papers, packaging components and related materials in fields such as food, pharmaceuticals, medical devices, daily chemicals, photovoltaic electronics, etc. It provides a wide range and high-efficiency oxygen transmittance detection for materials with high, medium and low oxygen barrier properties.

Operating Principle

The principle of the coulometric method is adopted. The pre-treated sample is fixed in the middle of the test chamber. High-purity oxygen flows in the upper chamber of the film, and high-purity nitrogen (carrier gas) flows in the lower chamber. Oxygen molecules diffuse through the film into the nitrogen on the other side and are carried by the flowing nitrogen to the sensor. By analyzing the oxygen concentration measured by the sensor, the oxygen transmission rate can be calculated.

Product Features

  1. High-precision imported oxygen sensor, with high sensitivity, ultra-high stability and extremely low failure rate, and a resolution of 0.0001cm³/(㎡·24h).
  2. Accurate and reliable test data: The test temperature is precisely controlled. Equipped with a high-precision temperature sensor, the temperature and humidity in the test chamber are stable, and the temperature control accuracy can reach ±0.5 ℃.The temperature, gas flow values and curves are monitored in real time during the test, and the test has high repeatability.
  3. Ultra-wide test range and high instrument applicability: The instrument is equipped with a single chamber, which is compact and flexible, saving space; with an ultra-wide test range of [0.005~1000 cm³/(㎡·24h)], it can meet the test requirements of high, medium and low barrier materials. With the addition of suitable accessories, it can measure the oxygen transmission rate of containers such as bottles, bags and bowls.
  4. Intelligent operating system with global certification: Self-developed intelligent operating system with modular diagrams, flexible setting of test process parameters, and intuitive and convenient operation; Designed according to the GMP appendix "Computerized Systems", it has an audit trail function and multi-level user authority settings, which can meet the data traceability requirements of the pharmaceutical industry; Personalized test reports can be set as required, supporting various data output formats, and the function of submitting audit reports online.

Technical Parameters

Item

Parameter

Measuring range

0.005 - 1000 cm³/(m²·24h)

Resolution

0.0001 cm³/(m²·24h)

Temperature range

5°C - 55°C

Temperature accuracy

±0.5°C

Carrier gas flow

5 - 100 mL/min

Specimen size

Φ 110 mm

Specimen thickness

≤3 mm

Gas source pressure

≥0.4 MPa

Oxygen pressure

0.1 MPa

Nitrogen pressure

0.1 MPa

Chambers/ Cells

1 pieces

Power

450 W

Power supply

AC 220V/50Hz

Permeation area

50.26 cm² (other options available)

Humidity range (optional)

0 - 90%RH (±2%)

Dimensions

470mm × 570mm × 400mm

Equipment Configuration

Standard Configuration

Power cord, communication cable, sample cutter, sealing grease, 3mm steel pipe

User-provided Items

Compressed air (pressure ≥ 0.4 MPa, interface Φ 8mm polyurethane tube), one cylinder of oxygen (purity must be over 99.99%, equipped with a pressure reducing valve, output range 0-0.4 Mpa), one cylinder of nitrogen (purity must be over 99.999%, equipped with a pressure reducing valve, output range 0-0.4 Mpa),computer.