LS Retort Sterilizer
Standards
GB150,GB/T10004,GB4793,YY1007-2010等
Application Fields
Packaging | Food | Pharmaceuticals | New Materials | Chemical Industry | Printing
Intended Use
Specifically designed for testing the high-temperature sterilization resistance of packaging materials, adhesives, and ink products. It is widely used by packaging manufacturers, film suppliers, food processors, inspection agencies, research institutes, and medical units.
Operating Principle
This product is designed based on dual-mode sterilization principles. It utilizes a heater to generate pressurized steam, which destroys microbial structures to achieve sterilization. When the rapid cooling program starts, tap water is injected and heated for approximately 25 minutes to enter the sterilization holding phase. After sterilization, 0.24 MPa compressed air and water are manually or automatically injected into the chamber for back pressure cooling, preventing flexible packaging from bursting due to pressure imbalances. The system then automatically manages water cooling and air pressure stabilization, followed by an alarm upon completion.
Product Features
- Fully Automated: Features automatic water intake, heating, temperature holding, timing, exhaustion, and back pressure control.
- Back Pressure Retort: Equipped with back pressure cooking functionality and a double-compartment design.
- Advanced Chamber Design: Optimized for thorough sterilization with anti-burst and anti-crack technology for delicate samples.
- Dual Cooling Modes: Utilizes both water spray and air cooling for high efficiency, ensuring superior cooking effects and rapid temperature transitions.
- Five-level Safety System: Includes water level, time, and temperature controls, with alarms and automatic power-off for low water or over-temperature conditions.
Technical Parameters
|
Item |
Parameter |
|
Chamber Volume |
35L (Optional: 50L, 75L, 100L) |
|
Max. Working Pressure |
0.22Mpa(30Psi) |
|
Max. Working Temperature |
135℃ |
|
Sterilization Temp. Selection |
105~135℃ |
|
Boiling Temp. Selection |
≤100℃ |
|
Timer Range |
1 ~ 99 hours 59 minutes |
|
Power / Voltage |
2.5 KW /AC220V ,50Hz;3 KW /AC220V ,50Hz;4.5 KW /AC220V ,50Hz; |
|
Dimensions |
570×550×970mm(35L);590×590×1110mm(50L);650×630×1150mm(75L);680×650×1220mm(100L) |
Equipment Configuration
Standard Configuration
Mainframe, One set of Spray System, One set of Specialized Wrenches, High-pressure Plastic Air Tubing.
User-provided Items
Compressed Air, Air Pressure Reducing Valve.